Transformer for switch mode power supply - 1700 VA


Catalogue HF as PDF
HF-transformer, HF-transducer, ferrite transformer, switch mode power supply, ETD 49 - ETD 59, 270 VA up to 1700 VA

hf-zeichen-sm


Switch mode power supplySwitch mode power supplySwitch mode power supply

open                                                            potted                                                     upright, open


Description


Design

Application

Voltages
Frequency
Core material
Temperatureclass
Temperature
Protective class
Winding

Construction
Terminals
Safety

HF-transformer conform to IEC/EN 61558-2-17 for SMPS
HF-transformer, HF-transducer, ferrite transformer, SMPS transformer
Suitable as HF-transformer for power integrations (TOPSWITCH, TINYSWITCH), Advanced Technology and ST(VIPer). HF choke can also be built
according to customer specification, more than one input and output voltages are possible
20 kHz up to 300 kHz, special types up to 500 kHz
N87 or PL7 for high power, with other materials it’s less power
F (155 °C) for varnished and B (130 °C) for potted components
Ambient 40 °C, higher ambient temperature decreases the power
Fire class UL94V0, IP00 conform to DIN 40 050
with lacquered copper wire, HF-litz, foil or triple insulated Furukawa wire, interlaced construction, for optimal magnetic coupling
varnished under vacuum(open Version) with class H varnish or potted under vacuum in a housing
Print, SMD version or free wires
Margins to redeem air and creepage distances. A screening is possible, but the secondary power will decrease.


Table


Type size

Frequency

Power - N87/PL7

Datasheet

Flyback

Forward

Push-pull

ETD 49

open

25 kHz

270 VA

315 VA

450 VA

PDF

50 kHz

366 VA

427 VA

610 VA

100 kHz

486 VA

567 VA

810 VA

ETD 49

standing

25 kHz

270 VA

315 VA

450 VA

PDF

50 kHz

366 VA

427 VA

610 VA

100 kHz

486 VA

567 VA

810 VA

ETD 49

potted

25 kHz

270 VA

315 VA

450 VA

PDF

50 kHz

366 VA

427 VA

610 VA

100 kHz

486 VA

567 VA

810 VA

ETD 54

open

25 kHz

390 VA

455 VA

650 VA

PDF

50 kHz

516 VA

602 VA

860 VA

100 kHz

690 VA

805 VA

1150 VA

ETD 54

potted

25 kHz

390 VA

455 VA

650 VA

PDF

50 kHz

516 VA

602 VA

860 VA

100 kHz

690 VA

805 VA

1150 VA

ETD 59

open

25 kHz

540 VA

630 VA

900 VA

PDF

50 kHz

750 VA

875 VA

1250 VA

100 kHz

1020 VA

1190 VA

1700 VA

ETD 59

standing

25 kHz

540 VA

630 VA

900 VA

PDF

50 kHz

750 VA

875 VA

1250 VA

100 kHz

1020 VA

1190 VA

1700 VA

Technical changes and optimisation reserved. All details are guide values, variations are possible.

03/2012


© 2018 Tauscher Transformatoren GmbH                                                                                                                                   Impressum / Privacy Policy