Technical data three-phase transformers


Construction
T.O = open, vacuum varnished


Temperature class
T40/B, on request insulation class F (155°C)


Protective class
IP00 (for mounting in an appliance)


Phases
3


Frequency
48 Hz up to 400 Hz, other frequencies than 50 Hz lead to another power at the same type size


Safety standards VDE/SEV
EN 61558


Safety standards UL/CSA
on request UL/CSA materials or UL-approval


Resistance to short-circuiting
conditionally short circuit protected with
- temperature fuse
- temperature switch
- mini fuse
in other case no resistance to short-circuiting


Bobbin
DIN 41302, 1 or 2 chamber versions
material: Polyamid 6 gf class B = 130°C with UL approval UL 94 HB


Insulants
Polyester class B = 130°C with UL approval UL 94 V0


Copper wire
Polyurethane mod. class F = 155°C with UL approval
min. 0,04 mm, max. flat copper with ca. 500 qmm


Screening
made of Cu-foil, reduces the max. power


Transformer core lamination
conform DIN 41302
M530-50A, 0,5 mm thick (1,0 W/kg losses at 1,7 T) or
M111-35N, 0,35 mm thick (1,1 W/kg losses at 1,5 T)


Terminals
Free wires
Stranded flexible wires
Terminal connectors
Plug pins
Cable lugs


Mounting
Base angle
Distance bolts
Holes in the core


Tappings
possible